Page 7-36 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
7.8 GDL 69 XM Data Link
Original GDL 69 is Reinstalled
No software or configuration loading is required if the removed GDL 69 is re-installed. This does not
include units that were returned for repair as their software and configuration files are deleted during the
repair testing process. Continue to Section 7.8.2 if the original unit with no repairs was reinstalled.
Continue to section 7.8.1 for repaired or exchanged units.
New, Repaired or Exchanged GDL 69 is Installed
If a new, repaired, or exchanged GDL 69 is installed, the correct software and configuration files must be
loaded to the unit, and then the XM Satellite Radio subscription must be reactivated. See the XM
Activation Instructions listed in Table 1-2. Continue to the software loading procedure.
7.8.1 GDL 69 Software and Configuration File Loading
If a new, repaired or exchanged GDL 69 is installed the correct software and configuration files must be
loaded. Follow the procedure below to load the files.
1. Remove the bottom SD cards from the displays. Note which one was removed from the MFD so
it may be identified later for reinsertion in the MFD when software and configuration loading are
complete. It might contain a FliteChart® or ChartView database which is only used in the MFD.
2. Insert the correct G1000 software loader card that matches the existing G1000 system software
version in the PFD top card slot.
3. Start the displays in configuration mode.
4. On the PFD, go to the System Upload Page using the small FMS knob.
5. Push the FMS knob to activate the cursor, then rotate the small FMS knob to display a drop-down
menu in the AIRFRAME field. Turn the small FMS knob to highlight OPTIONS in the menu
and press the ENT key.
6. Once an airframe type is selected the cursor moves to the FILE field. Rotate the small FMS knob
to activate the drop-down menu. Move the cursor to highlight DA 40 Option – GDL69 and press
ENT.
7. Press the CLR ALL softkey.
8. Using the FMS knob and ENT key, select the following files:
• GDL COMPATABILITY UPDATE – software file
• GDL SYSTEM – software and configuration files
9. Once the files are selected press the LOAD softkey.
10. When the upload is complete, press the ENT key to select OK in the upload complete window.
11. Verify that each column indicates in green when the loading process has finished and
inspect the SUMMARY window as well to ensure that the load is successful.
12. After the software and configuration files are loaded, turn off the system and remove the G1000
system software loader card. Reinsert the supplemental database cards in the bottom slot of each
display. Be sure to insert the card removed from the MFD back into the MFD.
13. Continue to the GDL 69 Testing section.
Commentaires sur ces manuels