Garmin G1000 Cockpit Reference Guide for the Beechcraft 58/G58
12-11
SECTION 12 – ANNUNCIATIONS
& ALERTS
GMA 1347 Alert Messages
Alerts Window Message Comments
GMA1 FAIL – GMA1 is inoperative. The audio panel self-test has detected a failure. The audio panel is unavailable. The
G1000 system should be serviced.
GMA1 CONFIG – GMA1 configuration
error. Config service req’d.
The audio panel configuration settings do not match backup configuration memory.
The G1000 system should be serviced.
MANIFEST – GMA1 software
mismatch. Communication halted.
The audio panel has incorrect software installed. The G1000 system should be
serviced.
GMA1 SERVICE
– GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in the unit. Certain audio functions
may still be available, and the audio panel may still be usable. The G1000 system
should be serviced when possible.
BACKUP PATHAudio panel 1 using
backup data path.
The #1 audio panel is using a backup communication path. The G1000 system
should be serviced when possible.
GIA 63 Alert Messages
Alerts Window Message Comments
GIA1 CONFIG – GIA1 configuration
error. Config service req’d.
The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GIA2 CONFIG – GIA2 configuration
error. Config service req’d.
GIA1 COOLING – GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA2 COOLING – GIA2 temperature
too low.
GIA1 COOLING – GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000
system should be serviced.
GIA2 COOLING – GIA2 over
temperature.
GIA1 SERVICE – GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a problem in the unit. The G1000
system should be serviced.
GIA2 SERVICE – GIA2 needs service.
Return the unit for repair.