Vue de la page 89
Garmin G1000 Cockpit Reference Guide for the Diamond DA42NG
190-00963-01 Rev. B
74
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GIA 63W MESSAGE ADVISORIES (CONT.)
Message Comments
GIA1 SERVICE
– GIA1 needs
service. Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a
problem in the unit. The G1000 system should
be serviced.
GIA2 SERVICE
– GIA2 needs
service. Return the unit for repair.
HW MISMATCH
– GIA hardware
mismatch. GIA1 communication
halted.
A GIA mismatch has been detected, where only
one is SBAS capable.
HW MISMATCH
– GIA hardware
mismatch. GIA2 communication
halted.
MANIFEST
– GIA1 software
mismatch, communication halted.
The GIA1 and/or GIA 2 has incorrect software
installed. The G1000 system should be serviced.
MANIFEST
– GIA2 software
mismatch, communication halted.
MANIFEST
– GFC software
mismatch, communication halted.
Incorrect servo software is installed, or gain
settings are incorrect.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The transmitter
is operating at reduced power. If the problem
persists, the G1000 system should be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
COM1 SERVICE
– COM1 needs
service. Return unit for repair.
The system has detected a failure in COM1
and/or COM2. COM1 and/or COM2 may still be
usable. The G1000 system should be serviced
when possible.
COM2 SERVICE
– COM2 needs
service. Return unit for repair.
COM1 PTT
– COM1 push-to-talk
key is stuck.
The COM1 and/or COM2 external push-to-talk
switch is stuck in the enable (or “pressed”)
position. Press the PTT switch again to cycle its
operation.
If the problem persists, the G1000 system
should be serviced.
COM2 PTT
– COM2 push-to-talk
key is stuck.