Garmin G1000 Cockpit Reference Guide for the Diamond DA42NG
190-00963-03 Rev. A 105
Annunciations & Alerts
Flight
Instruments EIS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
GIA 63W MESSAGE ADVISORIES (CONT.)
Message Comments
MANIFEST
– GFC software
mismatch, communication halted.
Incorrect servo software is installed, or gain
settings are incorrect.
MANIFEST
– COM1 software
mismatch, communication halted..
COM1 and/or COM2 software mismatch. The
system should be serviced.
MANIFEST
– COM2 software
mismatch, communication halted.
MANIFEST
– NAV1 software
mismatch, communication halted.
NAV1 and/or NAV2 software mismatch. The
system should be serviced.
MANIFEST
– NAV2 software
mismatch, communication halted.
COM1 CONFIG
– COM1 config error.
Config service req’d.
COM1 and/or COM2 configuration settings do not
match backup configuration memory. The system
should be serviced.
COM2 CONFIG
– COM2 config error.
Config service req’d.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The transmitter
is operating at reduced power. If the problem
persists, the system should be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
COM1 SERVICE
– COM1 needs
service. Return unit for repair.
The system has detected a fault in COM1 and/or
COM2. COM1 and/or COM2 may still be usable.
The system should be serviced when possible.
COM2 SERVICE
– COM2 needs
service. Return unit for repair.
COM1 PTT
– COM1 push-to-talk key
is stuck.
The COM1 and/or COM2 external push-to-talk
switch is stuck in the enable (or “pressed”)
position. Press the PTT switch again to cycle its
operation.
If the problem persists, the system should be
serviced.
COM2 PTT
– COM2 push-to-talk key
is stuck.
COM1 RMT XFR
– COM1 remote
transfer key is stuck.
The COM1 and/or COM2 transfer switch is stuck
in the enabled (or “pressed”) position. Press the
transfer switch again to cycle its operation. If the
problem persists, the system should be serviced.
COM2 RMT XFR
– COM2 remote
transfer key is stuck.
Commentaires sur ces manuels